Furnace Temperature Range | 0°C - 1450°C |
Temperature Controlling Accuracy | < 5°C |
Resolution | 1°C |
Sample Quantity | 5 samples each time |
Temperature Rising Speed | Comply with national standard. |
Laboratory Atmosphere | Oxidability or weak reducibility |
Power Supply | 220V, 50/60HZ |
Maximum Power | < 5KW |
Cabinet Dimension | 850mm×400mm×600 mm |
Working Principle | Isoperibol |
Type of bomb | Removable |
Operating oxygen pressure | 3-4 MPa (30 bars) |
Measuring Range | 500-10000 K.cal/Kg |
Working Temperature | 25° ± 5 ° C (Environment Controlled Conditions) |
Heat capacity | 14400 J/K~14500 J/K; |
Resolution | 0.001k |
Measurement accuracy | ± 60J/g |
Repeatability error | ?0.2% (Grade C) |
Pressure endured by oxygen bomb | 20 Mpa |
Temperature measurement range | 10°C~ 35°C |
Ambient Temperature | 20±5°, the temperature fluctuation should not be more then 1during a test; |
Data saved | 31 pieces |
Relative humidity | ?85% |
Power Supply | AC220V+5%, 50Hz |
Big Jambo LCD Display - 20*40 |
In Built Printer |
16 Soft Touch Keyboard |
Weight Of Mass Feet Able |
Water Equipments Feet Able |
Final Test Report Print Out With Resolution Of 0.001c. |
Alarms On Ting & Final Riding |
Fire Wire Open Detection |
No Paper Loaded Detection - Led Blink |
Real Time Clock |
Internet Data Logger With Computer Power On/ Off |
Automatic Measurement And Calculated Calorific Value Water Equivalent Micro Controller Based |
As per IS-1350 Part-II, ASTM-D5865 | |
Working Principle | ISoperibol. |
Test per hour | 4 |
Operation Time | 13-15 minutes... |
Operating Oxygen Pressure | 3-4 Mpa. |
Working Temperature | 20±3 C. |
Temperature Resolution | 0.01 C |
Power supply | 220V, 50HZ. |
Frequency | 50Hz. |
Power input | <1Kw. |
System structure | Automated, |
Standardization based on | Analysis of 1 gm of benzoic acid. |
Temperature Measuring Resolution | 0.0001 C. |
Precision | (RSD<0.05%) |
Analysis Time | 8-15 Mins. |
Repeatability of determination | (±) 25kcal/kg (for Coal standards). |
Oxygen operating pressure max | 4 Mpa. |
Type of bomb | Removable. |
Bucket filling | Automatic. |
Water handling | Fully Automated |
Interfaces | USB Port for PC Rs-232 for balance USB for printer. |
GCV range | Upto 12000 kcal/kg. |
Weight | 80 kg approx. |
Heat Capacity | (14000~15000) J/K; |
Temperature Resolution | 0.001 K; |
Thermal Error | <60j/G; |
Temperature Measurement Range | 10oC~35oC; |
Repeatability Error | <0.2% (Grade C); |
Pressure Endured By Oxygen Bomb | 20 Mpa |
Ambient Temperature | 15 oC~28 oC (Room Temperature), The Temperature Fluctuation During Each Test Should Be Not More Than 1oC; |
Ambient Humidity | Less Than 85%; |
Power Supply | AC(220±5%)V, 50hz; |
Total Power Consumption | Less Than 150w. |
Dimensions | 600 Mm × 460 Mm × 430 Mm (Length × Width × Height, Pc Is Not Included) |
Temperature Measuring Resolution | 0.0001 C. |
Precision | (RSD<0.05%) |
Analysis Time | 8-15 Mins. |
Repeatability of determination | (±) 25kcal/kg (for Coal standards). |
Oxygen operating pressure max | 4 Mpa. |
Type of bomb | Removable. |
Bucket filling | Automatic. |
Water handling | Fully Automated |
Interfaces | USB Port for PC Rs-232 for balance USB for printer. |
GCV range | Upto 12000 kcal/kg. |
Weight | 80 kg approx. |
Spindle Speed RPM: 20±1 r/min |
Working Revolution: 60 |
Ball Diameter: 25.4±0.13 mm |
Grinding Bowl Capacity: 50g |
Operation On: 220/230V, 50/60Hz |
Load Bearing Capacity: 284±2N |
Feed Size: 0.63-1.25mm |
Number of Grinding Balls: 8 |
Grinding balls MOC: Chrome Steel |
The equipment must have a micro-computer intelligent controlling system |
The machine must have a LCD screen with film key for easy operation |
The Pulverizer Is Supplied Complete With A 3 H.P. Motor, Starting Switch, V-Belt Puly Drive And Mounting. Electrical Requirements Are 440 Volts, 3 Phase A.C. |
Disc Diameter : 175mm. |
Maximum Feed Size : 8 Mm (Approx) |
Size Of Finished Product: 72 Mesh (212 Microns). |
Movement :Vertical Plane. |
Model no | AI-SS-174 |
Applications | Separation, Fractioning, Particle Size Determination |
Display | Bright LED Display |
Sieving | Both Dry and Wet |
Sieve Diameter | 200 |
Vibration Frequency | 1420 times/minute |
Measuring Range | 0.038 4mm |
Mode Selection | Continuous |
Max. Batch / Feed Capacity | 2 kg |
Programmable Time | 1 to 99 min |
Vibration Amplitude | < 5mm |
Noise | 50 DB |
Power | AC 220V 125W |
Weight | 25 kg (without test sieves) |