Weighing capacity | : | 220 g |
Readability | : | 0.1mg |
Repeatability | : | = 1mg |
Pan size | : | 90mm |
Power | : | 230 V ± 10% 50Hz |
Weighing capacity | : | 220 g |
Readability | : | 0.0001 g |
Repeatability | : | = ±0.0001 g |
Linearity | : | = ±0.0002 g |
Pan size | : | 90 mm |
Power | : | 110 V ± 10% 60Hz 10VA |
Actual Dimensions | : | 320 W X 200 D X 300 H mm |
Flame with deuterium background correction |
Six lamps automatically rotating tower |
Automatically setting slits, lamp current |
Flame titanium atomized; |
Six hollow cathode lamp included |
Workstation software |
Oilless Air Compressor |
Acetylene Gas cylinder with Regulator (empty) |
Compatible computer with printer Scanner |
Instrument Type | Single Beam Reflection Achromatic Optics System |
Monochromator | Aberration Corrected Czerny-Turner |
Dispersion elements | Grating system 1200 line/mm characterization area 40mm2 Scintillation wavelength 250nm |
Bandwidth | 0.1, 0.2, 0.4, 1nm (4 step auto switching) |
WL Range | 190-900 |
WL Accuracy | ±0.2 |
Resolution | ±0.1 nm max |
HCL housing | Standard 4 lamp turret. |
Photometric Range | 0-125%, -0.1-3.00A |
Static Baseline Drift | (Cu) +-0.003 A/30min |
Dynamic Baseline Drift | (Cu) +-0.006 A/30min |
Background Correction | High speed self-reversal (BGC-SR) method: High speed D2 lamp method (BGC-D2) |
Characteristic Concentration | (Cu) 0.025 Êg/ml max |
Detection limit | (Cu) 0.004 Êg/ml max |
Power (Main unit with(Flame) | AC 220 V ±10%, 50 Hz without sharp fluctuations |
Working Temperature range | 1 0~30 C |
Working Humidity range | 40%~85% |
Parameter | Conductivity | Temperature |
Range | 0 to 200uS/cm, 0 to 2mS, 0 to 20mS , 0 to 200mS, 0 to 1000 mS/cm | 0°C to 100°C |
Resolution | 0.1 .uS /cm | 0. 1°C |
Accuracy | ±0.5% ±1 digit. | ±0.1°C ± 1 Digit |
Temp .Compensation | 0-100°C Manual & Automatic | |
Data Entry | By soft touch keys | |
Display | 16x2 LCD | |
Input Resistance | 10 ^12 ohms | |
Input Frequency | 1000Hz | |
Cell Constant compensation | Adjustable | |
Power Supply | 230 V ±10%, 50 Hz AC. 12 VDC( Optional) | |
Ambient Temperature | 10°C to 50°C | |
Dimensions (L x B x H)mm | 270 x 202 x 80 mm. Weight: 1.0 Kgs | |
Accessories | Conductivity Cell, Dust Cover, Instruction manual, Standard solutions. |
PARAMETER | NA | K |
RANGE | 0.1 - 100 PPM UP TO 250 MEQ /L, 1:100 DIL SERUM 0 - 200 , 1:100 DIL URINE 0 -250 1:100 DIL |
K: 0.1 - 100 PPM UP TO 250 MEQ/L, 1:100 DIL SERUM 0 - 10, 1:100 DIL URINE 0 - 100 1:100 DIL |
SENSITIVITY | 5 PPM | 5 PPM |
RESOLUTION | 0.1PPM/ MEQ | |
REPRODUCIBILITY | ± 2 % OF RANGE ± 1 DIGIT. | |
CURVE FIT ACCURACY | ± 2 % OF RANGE ±1 DIGIT. | |
CALIBRATION | UP TO 5-POINT CALIBRATION WITH CURVE FITTING SOFTWARE . | |
DETECTOR | SILICON PHOTODIODE | |
DISPLAY | 128 X 64 GRAPHICAL LCD DISPLAY | |
FILTERS | NA & K INCLUDED. LI & CA AT AN EXTRA COST | |
IGNITION | AUTO IGNITION | |
GAS CONTROL | FULLY ADJUSTABLE | |
ATOMIZER | BLACK BACK ELITE , AXIAL FLOW TYPE | |
DISPLAY | 128 X 64 GRAPHICAL LCD DISPLAY | |
POWER SUPPLY | 230 V + 10% AC, 50/60 HZ | |
DIGITAL OUTPUT | RS 232 C PC SOFTWARE | |
DIMENSIONS | 365 X 245 X 220 MM (L X B X H)(APPROX.), WEIGHT : 8 KGS | |
COMPRESSOR UNIT | ||
AIR SUPPLY | OIL FREE COMPRESSOR UNIT WITH PRESSURE REGULATOR | |
GAS | LPG CONTROLLED BY PRECISION REGULATOR | |
POWER SUPPLY | 230 V + 10% AC, 50/60 HZ | |
DIMENSIONS | 290 X 225 X 220 MM (L X B X H)(APPROX.), WEIGHT : 8 KGS | |
ACCESSORIES | INSTRUMENT WITH NA &K FILTERS , INSTRUCTION MANUAL, CHIMNEY, AIR AND GAS TUBING ALONG WITH CLAMP, SAMPLE HOLDER |
Lab Heating Plate Rectangular with Cast Iron Top. |
Temp. upto 350 Deg C., With E.R. |
Size: 25 x 30 x 15 cm 1.2 KW |
kjedahl Digestion & Distillation Unit |
Combined, Mantle Type |
Unit for 12 test with E.R. |
Glass Part & Clamps for 12 test (Set) |
Function | Ph Or Mv & Temperature Simultaneously |
Display | Digital Led |
Power Supply | 230 V ± 10% 50 Hz Ac |
Ph Range | 0 To 14 Ph |
Resolution | 0.01 Ph |
Accuracy | ± 0.01 Ph ± 1 Digit |
Slope Adjustment | 80% To 120% By Default 100% |
Temp.Compensation | 0 To 100 C Auto With Temp Probe / Manual With Keys |
Auto Buffer Recognition | 4.00 Ph, 7.00 Ph,9.20 Ph |
Calibration | Auto As Manual, 3 Point / 2 Point (Programmable) |
Mv Range | -1999 Mv To +1999 Mv |
Resolution | 1 Mv |
Accuracy | ± 0.1% ±1 Digit |
Calibration | Two Point Manual |
Material | : | Fabricated Assembly From Heavy Mild Steel (MS) Section Duly Paint/ Powder Coated. |
Duty Cycle | : | Continuous |
Optional | : | Digital RPM Meter With DC Drive Spare Tray For Above Unit With Different Capacity |
Power Consumption | : | 220/230V AC Supply ± 10% Single Phase 50HZ |
Capacity | : | 25 Flask Of 250ml |